Problem in NE80E about Received reset fragment

Publication Date:  2012-07-27 Views:  34 Downloads:  0
Issue Description
There is an alarm message appering very frequently in logbuffer about "Received reset fragment".
Alarm Information
%Nov 28 12:13:50 2007 ISB-PE-NE80E-A SOCKET/5/SOMONLOG:
Received reset fragment: (task=ROUT(27),socket=43(TCP),proto=6,state:Syn_Sent, LA = 117.20.23.129:49240, FA = 117.20.23.130:179, Statistics:Input=1,Recv=0,Output=1;Window close:started at 12H13M50S,total=1;Block:started at 12H13M50S;)
Handling Process
The problem is solved after removing the unused peer configuration 
[N80E]undo peer 117.20.23.130 as-number 23674
      
Root Cause
This message is about the TCP, which was caused by the BGP peer building abnormally.
bgp 38193 
peer 117.20.23.130 as-number 23674
We have to check whether the BGP peer was configed normally.
Suggestions

Null