GE interface turns to down and up state Continuously

Publication Date:  2012-07-27 Views:  33 Downloads:  0
Issue Description
HYD_NE40-8 connected with MGW through GE link. In between of NE40 and MGW we have ODF.
Fiber type LC- SC.
NE40-8 Version: VRP (R) software, Version 5.30 (NE40&NE80 V300R002C01B551.
We connect the NE40-8 to ODF through a fiber cable( LC- SC).and MGW is connect with this ODF through LC-SC fiber cable.
After making connection b/w NE40 and MGW we receive alarm GE 3/0/0 come to down state and it again went up within one second. And this comes again an again on NE40-8.
Alarm Information
%Nov 28 14:57:37 2007 PTCL_HYD_NE40 IFNET/5/UPDOWN:Interface GigabitEthernet3/0/0 Turns into DOWN state
#Nov 28 14:57:39 2007 PTCL_HYD_NE40 SRM/5/TRAP:1.3.6.1.4.1.2011.5.25.37.2.114 Interface 201326849 Turns into Physical Up state
#Nov 28 14:57:39 2007 PTCL_HYD_NE40 IFNET/5/TRAP:1.3.6.1.6.3.1.1.5.4 Interface 903 Turns into Up state
#Nov 28 14:57:40 2007 PTCL_HYD_NE40 IFNET/5/TRAP:1.3.6.1.6.3.1.1.5.4 Interface 201326849 Turns into Up state
%Nov 28 14:57:40 2007 PTCL_HYD_NE40 L2IF/5/L2IF UPDOWN:Switch Port[GigabitEthernet3/0/0] state changed to UP.
Handling Process
we try to give a loop from ODF to NE40-8 and we find that this fiber is ok and connectivity b/w ODF and NE40-8 is ok as well.
We give a loop from ODF to MGW and it seems that it is also ok but after carefull examination we find that at MGW we have GE link on MG10 card and this port went down and up again with one second.
When we analyze the alarm panel we find an alarm "interface fault" message. 
We installed new fiber cable between ODF and MGW  and check again by giving loop. but again the same problem.
here we concluded that it was some port problem of MG10 board.
We replace the MG10 card and the problem was solved.
Find the attached file for alarm message at NE40-8
      
Root Cause
Port problem at MG10 card of MGW.because after replacing the card problem was solved
Suggestions
Null 
      