Interconnection Between EFS4 Board Port of OptiX 155622H(Metro1000) and RTU Ethernet Port of S Vendor

Publication Date:  2012-07-24 Views:  40 Downloads:  0
Issue Description
In the OptiX 155/622H(Metro1000), the SCC version was 4.02.06.41, the EFS4 version was 2.10, and Ethernet LAN was configured. After the interconnection with the RTU Ethernet port of S vendor, the port interconnection service is normal. But the interconnection port of the EFS4 board reported ETH_LOS (Ethernet signal loss) alarm. This alarm ended every three minutes and then was reported again. This alarm results from the loss of the port Ethernet signals, service interruption or abnormality. After the test, the interconnection service was normal.       
Alarm Information
The interconnection board of the EFS4 board reports the ETH_LOS alarm. This alarm ends every three minutes and then is reported again.       
Handling Process
1. Change the Port interconnection rate. The fault persisted.
2. Run the command ethn-cfg-portbdpara:3,ip3 to check whether the NMS made a wrong report. A normal report was detected.
3. Reset the EFS4 board. The fault persisted.
4. Run the RMON tool of the NMS to test the service and find that packets were sent and received normally. It indicated that the interconnection service was normal. After the long-time test, the packet was not lost.
5. Query the NE alarm. Find that the port alarm reversion was enabled. Disable the alarm reversion. The ETH_LOS alarm ended.
      
Root Cause
This alarm results from the loss of the port Ethernet signals, service interruption or abnormality. After the test, the interconnection service was normal.      
Suggestions
After the service is configured, you should not invert the generated alarms.      