Drift of Window of ONU alarm

Publication Date:  2012-07-24 Views:  70 Downloads:  0
Issue Description
We have the alarm "Drift of Window of ONU alarm" in MA5600T system and I found this description:
Description:
Multiple types of alarms are specified in the GPON protocol. If a GPON port detects that the upstream frame of an ONU arrives at an unexpected position and the position differentiation is within eight bits, the system generates this alarm.
Impact on System:
The device automatically adjusts the ONU delay according to the differentiation.
Possible Causes:
Change in the temperature causes the change of fiber in length.
Handling Procedure:
No need to proceed.
Related Information:
The optical network unit (ONU) and optical network terminal (ONT) are both the user-side devices of the optical line terminal (OLT) and they are both referred to as ONU.
 
Like it is stated in above the possible cause is temperature change. I am supposing that this is related with the laser.
1. The change's temperature can be both sides OLT and ONT, or only OLT, or ONT?
2. What is the variation of the temperature that can cause this?
3. The Drift of Window has any impact on the service of the client?
Alarm Information
Drift of Window of ONU alarm
Handling Process
1. The change's temperature can be both sides OLT and ONT, or only OLT, or ONT?
Re:Enviroment temperature can affect the fiber generally, it takes little effect on both OLT and ONT
2. What is the variation of the temperature that can cause this?
Re:
Because the silicon dioxide of fiber is not well conductor of heat ,so we can not easily evaluate the variation of the temperature  that can cause this alarm at lab. During our temperature-circle test(from-5 Celsius to 55 Celsius,with temperature shift rate of 1 Celsius per minute,and the fiber's length is 20 KM ), we have seen such alarm called  "Drift of Window of the ONU" about per 3 or 4 minutes.
The fiber shifts when the temperature's shift,if the fiber is very long (such as 20 KM),there should be such alarm even the temperature has only changed 1Celsius, but if the fiber is only 1 KM long ,the alarm will not appears whatever the temperature changes (from -40 Celsius to 85 Celsius).
 
3. The Drift of Window has any impact on the service of the client?
Re:OLT will adjust the report time of the ONT after received this alarm. The Drift of Window has no impact on the service of the client.We do not need to worry about this alarm.
      
Root Cause

Null

Suggestions

Null

END