The LPU of the NE40 Cannot Be Registered Because the ATM Sub-Card Is Mixed

Publication Date:  2012-07-27 Views:  37 Downloads:  0
Issue Description

The LPU is expanded at one site. An LPU, an ATM sub-card, and a GE sub-card are used together. The board cannot be registered after installation.

      
Alarm Information

%Dec 18 18:05:03 2007 Quidway SHELL/5/LOGIN: Console login from con0

%Dec 18 18:05:00 2007 Quidway SRM/5/DEMInure:Slot 2 DEM channel 2 inures%Dec 18 18:05:00 2007 Quidway SRM/5/DEMInure:Slot 2 DEM channel 1 inures!%Dec 18 18:04:59 2007 Quidway SRM/5/DEMInure:Slot 5 DEM channel 2 inures!
%Dec 18 18:04:59 2007 Quidway SRM/5/DEMInure:Slot 5 DEM channel 1 inures! 

Handling Process

1. Replace the slot and the fault persists.

2. The board can be registered if only one service sub-card exists. 

Root Cause

The ATM sub-card cannot be used with other types of sub-cards.

Suggestions

Null