The Orderwire Phone Fails to Get Through Because the SC2 Is Inserted in the Standby Subrack

Publication Date:  2012-07-24 Views:  56 Downloads:  0
Issue Description
An orderwire phone is connected to the EOW port of the SC2, but no sound can be heard on the orderwire phone. The T2000 has no relevant option during the configuration of the orderwire phone.
The NE software is 5. 51.01.15.       
Alarm Information
The orderwire phone cannot get through.      
Handling Process
1. Check that the orderwire phone is normal.
2. Check that the SC2 is normal.
3. Check whether other NEs have no relevant T2000 interface. The active subrack has relevant interfaces, but the SC2 installed in the standby subrack has no relevant orderwire interface.
4. The orderwire phone can get through only when the SC2 is installed in the active subrack of the OSN 6800. The solution is to install the SC2 in the active subrack.
5. After the SC2 is installed in the active subrack, the orderwire phone still has no ring. After an offhook, the run indicator of the phone is off. Maybe the SC2 fails or the equipment does not support the function.
6. After confirmation, the NE software versions 5.51.01.14 and 5.51.01.15 for the OSN 6800R1 do not support orderwire phones.       
Root Cause
1. The orderwire phone fails.
2. The SC2 fails.
3. The equipment does not support the orderwire phone without the relevant interface on the T2000.       
Suggestions
Add related documents about orderwire phones to the deployment guide.            