FAQ-how to solve the problem that CRC check values of active and standby boards are inconsistent

Publication Date:  2012-07-24 Views:  46 Downloads:  0
Issue Description
Q:
How to solve the problem that CRC check values of active and standby boards are inconsistent?
Alarm Information
Null
Handling Process
A:
When we execute "display data sync state" command, we found the CRC check values of active and standby boards are inconsistent:
UA5000(config)#display data sync state                                          
  All of configuration data (such as data originated from user configuration) synchronizes completely                                                         
  All of basic operation data (such as device status data, operation log and alarm, etc.) synchronizes completely                                            
  All of dynamic service data(data realtimely changing such as PSTN call data and PPPOE call data,etc.) synchronizes completely                               
  User configuration data CRC check values of active and standby boards are inconsistent
You can solve this problem as following:
1 Execute save command after data between  active and standby boards synchronizes completely.
2 If the problem can not be solved, please execute duplicate command to duplicate the data from active board to standby board, and then reboot standby board.
3 Reload the database to standby board.
Root Cause
Null
Suggestions
Null