Optical FiberCable cut happen but the Fiber Shows Green on NMS between Two Nodes

Publication Date:  2012-07-24 Views:  51 Downloads:  0
Issue Description
On NMS Optix IManager T2000  2-FMSP ring is created. 
Flow of Network
Site-A                                                                   Site-B
 OSN-7500-T2SL64--BWS-1600G-LWF..........BWS-1600G--LWF-OSN-7500-T2SL64
At NMS Fiber is created b/w Two NG-SDH Nodes of Site A and Site-B
Site-A                                                             Site B
OSN-7500-T2SL64---------------------------T2-SL64-OSN-7500
So when the fiber cut in b/w Two Nodes, so the R-LOS alarm appear on LWF board of BWS-1600G and on T2SL64 board show MS-RDI alarms. but the Fiber b/w Two OSN-7500 Nodes is shows Green.
Alarm Information
R-LOS
MS-RDI alarms.
Handling Process
After analysis found that ALS function is disable b/w Two Nodes, so then we have enable the ALS function. After that when Optical Fiber cut happens b/w Two Nodes at the same time Fiber shows read b/w Two NG-SDH Nodes and also R-LOS appears on LWF and T2SL64 Board.
Reason to Enable the ALS function is,
When no optical signals are input to the WDM side of the OTU board, the OTU board automatically shuts down all the lasers for the output optical interface on the client side with the ALS function enabled
Root Cause
When the Optical Cable cut happen b/w Two Nodes so Fiber is color shows Green on NMS, 
Flow of Network
Site-A                                                                   Site-B
 OSN-7500-T2SL64--BWS-1600G-LWF..........BWS-1600G--LWF-OSN-7500-T2SL64
At NMS Fiber is created b/w Two NG-SDH Nodes of Site A and Site-B
Site-A                                                             Site B
OSN-7500-T2SL64---------------------------T2-SL64-OSN-7500
2FMSP ring created b/w NG-SDH nodes at NMS, so when Optical cable cut happen at that time NMS reports R-LOS on LWF and MSRDI alarm on T2SL64 board but fiber is shows Green b/w Two OSN-7500 nodes.
The ALS function applies only to the output optical interfaces on the WDM side and the client side of the OTU board. This function can be enabled or disabled through the network management system
Suggestions
ALS Function enable only when Metro DWDM Nodes. if you have a Long Haul Network so then no need to enable the ALS function. Because the Fiber read shows b/w DWDM Nodes and also b/w NG-SDH so you will not able to locate to which site Optical cable cut happen.
Wavelength is passing through b/w several nodes like
Site A---Site-B-----Site-C-----Site-D----Site-E-----Site-F
IF the wavelength add/drop b/w site A and F, IF the fiber cut happen b/w Site-E and Site-F so you can easily trouble shoot the section by checking DWDM Nodes Fiber creation b/w Two Node.
Secondly you has enable the ALS function, so its mean fiber show read b/w NG-SDH nodes from Site -A to Site-F. Difficult to trouble shoot.