Testing of RS232 and RS422 serial ports without additional special tester

Publication Date:  2012-07-24 Views:  50 Downloads:  0
Issue Description
Customer require us to test RS232 and 422 serial ports in NG-SDH equipment (S1, S2, S3, S4 ports in AUX board).
But it need additional (special) expensive testers that can test RS232 and RS422 signals. 
Now we want to make this test procedure more simple, that do not require new special testers.
RS232 can be tested by Notebook COM-port using "Hyper-terminal" application of Windows, using optical loopback on-site (it is described in official manual - attached):
Laptop_COM_port <-> RS232 <-> optical_port <=> inloop
It make test method very simple and do not require special tester. 
But for RS422 test, we need new tester (RS422 signal) and connect 2 sites (as it is decribed in official manual). 
But, if we can translate RS422 to RS232 by some adapter, then we can use Notebook COM-port as in previous method:
Laptop_COM_port <-> RS232-adapter-RS422 <-> optical_port <=> inloop
Questions: 
1) Is it posible to test RS422 in single station using optical inloop ?
2) Is it possible to translate RS422 to RS232 by some adapter ?
Alarm Information

Null

Handling Process
---------- Testing of RS232 without special tester: ----------
RS232 can be tested by Notebook COM-port using "Hyper-terminal" application of Windows, using optical loopback on-site (it is described in official manual - attached):
PersonalComputer_COM_port <-> RS232 <-> optical_port <=> inloop
It make test method very simple and do not require special tester. 
----------- Testing of RS422 without special tester: ---------
PersonalComputer_COM_port ----(RS232:S1~S4)NGSDH_NE1 ----- Fiber connection ----- NGSDH_NE2(RS422:S1~S4, physical in-loop the used port by cable).
And then you can test the remote NGSDH_NE2 RS422 using "Hyper-terminal" application on PersonalComputer, just same as RS232.
Root Cause
We can't find the RS422->RS232 adapter you refered because these two kind of signal modes are different entirely. You can use the procedure to reach your purpose as following:
PC----(RS232:S1~S4)NGSDH_NE1-----Fiber connection-----NGSDH_NE2(RS422:S1~S4, loop the used port by cable).
And then you can test the remote NGSDH_NE2 RS422 using "Hyper-terminal" application, just same as RS232.
Suggestions
Null

END