Q:
What are related H248 signaling messages for AG dual-homing switchover? 
Alarm Information
Null
Handling Process
A:
1. Signaling messages sent by the AG to the active SoftSwitch for automatic dual-homing switchover: 
T=35784078{C=-{SC=ROOT{SV{MT=DC,V=2,RE="909",20060918T10120943}}}}
2. Signaling messages sent by the AG to the standby SoftSwitch for automatic dual-homing switchover:  
T=611733816{C=-{SC=ROOT{SV{MT=FL,V=2,RE="909",20060918T10144143}}}}
3. Signaling messages sent by the SoftSwitch for manual dual-homing switchover: 
T=1065444{C=-{SC=ROOT{SV{MT=HO,V=2,MG=[10.15.133.1]:2944,RE="903",20061213T10372000}}}}
4. Signaling messages replied by the AG to the SoftSwitch for manual dual-homing switchover:  
T=1065444{C=-{SC=ROOT{SV{MT=HO,V=2,RE="903",20061213T10291200}}}}