No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

problem in login to equipment

Publication Date:  2012-07-24 Views:  61 Downloads:  0
Issue Description
I stared to commission the new Metro1000V3 device. First time, I tried to change the ID and IP by Navigator. It was successful when its login name was szhw. But when I tried to work in T2000, there was a problem. I used the "admin" login to create the equipment. The login procedure was successful (I got “login successfully” message box) but when I decided to do "manual config", the "equipment is not logined" was appeared.
Alarm Information
Null
Handling Process
I did “upload” in T2000 in first time to match data between T2000 and equipment. Fortunately after uploading, I could do “manual config”. I used “initializing NM side Data” to approach to manual config.
Root Cause
One mismatch and mis-consistence between T2000 database and equipment caused the problem. 
Some times when you login to an equipment for first time, you may have this problem which doesn't let you to create boards, protection, so forth. I had similar problem in these days when I wanted to login to OSN 2500 for first time.
Suggestions
Null

END