FAQ-How does the UA5000 R11 trace the H248 signaling directly on the equipment

Publication Date:  2012-07-24 Views:  35 Downloads:  0
Issue Description
Q:
How does the UA5000 R11 trace the H248 signaling directly on the equipment?  
Alarm Information
Null
Handling Process
A:
1. Log in to the equipment using the account hwmusa. 
2. Enter the diagnosis mode by using the command diagnose. 
3. Enable the DBWIN and signaling trace. 
The commands are as follows:
UA5000(config)#diagnose 
UA5000(diagnose)%%dbwin enable 
UA5000(diagnose)%%mgtrace protocol h248protocol range mgall mg 0
Trace Setupped
Trace Parameters as fllow:
  Protocol Type: MeGaCo/H.248
  Trace Status: Active
  Trace Range: All Commands for MG
  MG ID: 0
Because this mode of signaling trace consumes many resources, you need use the following commands to disable it after signaling tracing: 
UA5000(diagnose)%%undo mgtrace 
Trace stopped
UA5000(diagnose)%%dbwin disable 
UA5000(diagnose)%%
Root Cause
Null