FAQ-How to identify the mapping relationship between the interface board HWCB and E1 resources of the UA5000G main control boards

Publication Date:  2012-07-24 Views:  50 Downloads:  0
Issue Description
Q:
How to identify the mapping relationship between the interface board HWCB and E1 resources of the UA5000G main control boards (PVU4/8, RSU4/8, and PVMB)?
Alarm Information
Null
Handling Process
A:
1. The E1 output ports of the HWCB are classified into E1 interface A (upstream ports 0�3 and 8�11) and E1 interface B (downstream ports 4�7 and 12�15). 
2. The mapping relationship between HWCB and PVMB/PVU4/RSU4 is as follows: 
E1s 0�3 of the HWCB correspond to the E1s 0�3 of the PVMB in slot 4 (E1 interface A). 
E1s 8�11 of the HWCB correspond to E1s 0�3 of the PVMB in slot 4 (E1 interface A). 
The relationship of port numbers between PVU4/RSU4 and PVMB is the same except that the slot of the main control board is different. The PVMB E1 status can be queried by using the command display e1State. 
3. The mapping relationship between HWCB and PVU8/RSU8 is as follows: 
E1s 0�3 of the HWCB correspond to E1s 0�3 of the PVMB in slot 4 (E1 interface A). 
E1s 4�3 of the HWCB correspond to E1s 4�7 of the PVU8/RSU8 in slot 4 (E1 interface B). 
E1s 8�11 of the HWCB correspond to E1s 0�3 of the PVU8 in slot 5 (E1 interface A). 
E1s 12�15 of the HWCB correspond to E1s 4�7 of the PVU8/RSU8 in slot 5 (E1 interface B).
Root Cause
Null
Suggestions
Understanding the E1 physical connections is good for troubleshooting. 

END