FAQ-Why the traffic calculate by Netflow is bigger than by Radius server

Publication Date:  2012-07-27 Views:  47 Downloads:  0
Issue Description

Topology:
subscriber------ME60----Router(Vendor C)----Internet
ME60 send traffic by Radius, and in The router , using Netflow to statistic traffic. but the value by Netflow is bigger than by Radius.
Q:Why the traffic calculate by Netflow is bigger than by Radius server?

Alarm Information

Null


Handling Process

A:
In configuration, we found that subsriber rate was limited by CAR . If the rate of down data from Internet  is larger than the value we limit,  ME60 will discard the packets, actually the discarded packets will be caculated by Netflow,  as a result, the total traffic which statistic by Radius is lower than by Netflow.

Root Cause

Null


Suggestions

Null

END