There is one warning TEST_STATUS on the cross-connect board.

Publication Date:  2012-07-24 Views:  59 Downloads:  0
Issue Description
There is TEST_STATUS warning on 9-EXCSA board of OSN 3500. Please tell the command to cancel the test status.
Alarm Information
TEST_STATUS
Handling Process
1.checked the documents for such alarm
2. the alarm is cause of opening the test mode on the equipment for special command execution
3. found from the document ptp command to close
4. run the command :optp:9,0,77,1,30,08,e7,e7,e7,a5,a5,a5;
5.alarm disappeared
Root Cause
someone entered the test state to do some ptp command for degrade or for some precaution and forgot to close...
to exit test state is  :optp:9,0,77,1,30,08,e7,e7,e7,a5,a5,a5;
Suggestions
 run the command :optp:9,0,77,1,30,08,e7,e7,e7,a5,a5,a5;

END