Port SD567 interruption check (interrupted register)

Publication Date:  2012-07-27 Views:  30 Downloads:  0
Issue Description
Following  error  was observed during routine inspecion on NE40E Routers using DC OM tool
1: Port SD567 interruption check
efu 567 1 display interrupted-register
SD567_TOP_INT_FLAG : 0x0001
     bit 0 -> IOPI_INT_FLAG : 0x000f
          bit 0 -> IPI_INT_FLAG0 : 0x0436 
          bit 1 -> IPI_INT_FLAG1 : 0x0436 
          bit 2 -> IPI_INT_FLAG2 : 0x0436 
          bit 3 -> IPI_INT_FLAG3 : 0x0436 
[GWL-PE-NE40E-A2-diag-ne5000]
================================================================================================================
efu 567 1 display interrupted-register
SD567_TOP_INT_FLAG : 0x0001
     bit 0 -> IOPI_INT_FLAG : 0x000f
          bit 0 -> IPI_INT_FLAG0 : 0x0436 
          bit 1 -> IPI_INT_FLAG1 : 0x0436 
          bit 2 -> IPI_INT_FLAG2 : 0x0436 
Almost same output for other cards.
Alarm Information
There was no alarm on system.
Problem was observed during routine inspection using DC OM Tool.
Handling Process
when i type this command 1~2 times, the shown interupt result was caused by the initiation of the router. So this command is only meaning when you type many times, if the values being diplayed by this command is not zero then  it means there is some problem. 
[NE40E-A1-diag-ne5000]efu 567 1 display interrupted-register
SD567_TOP_INT_FLAG : 0x0000
[NE40E-A1-diag-ne5000]efu 567 1 display interrupted-register
SD567_TOP_INT_FLAG : 0x0000 
In above traces the value is zero it means there is no problem. 
We need to run this command for four or five times and then observe the output whether it is zero or non zero. 
On all router output was same as below
0x0000 
Value is zero it means no problem.
Root Cause
Port SD567 interruption check running following command in diagnostic mode 
efu 567 1 display interrupted-register it show ouput 
SD567_TOP_INT_FLAG : 0x0001
it means there is some problem with slot id 1.
Suggestions
Do not run any other command in hidden mode wothout approver from datacomm experts in R & D.

END