FAQ-possibility to have protection on Gigabit Ethernet traffic

Publication Date:  2012-07-24 Views:  48 Downloads:  0
Issue Description
the customer haveOSN3500 with EGS2 board and  want to apply protection level for GE traffic same as TPS 
they think they can make EPLAN service and add 2 Gi port for comman virtual bridge (VB) so that if one port fail the other port protect it. but we still have problem if this board itself became faulty (i.e EPLAN V.B is not enough for redundancy).
Alarm Information
Null
Handling Process
for EGS4 it supports the board and port protection starting from V1R6 
The Board Protect Switch (BPS): Uses an active and a standby board. When the active board is faulty, the services are automatically switched to the standby board.
Port Protect Switch (PPS): Uses an active and a standby board, which is similar to BPS. The difference is that only services on faulty ports are switched but services on other ports is not.
Root Cause
solution of EGS2 adding two ports in the same EPLAN is not efficient and don't protect the board failure .
the EGS2 is not suitable for Protection but the new feature is added on EGS4
Suggestions
Null