FAQ-MSP switching time for SDH equipments

Publication Date:  2012-07-24 Views:  36 Downloads:  0
Issue Description
MSP Protection Switching Time test is done with Customer for STM-16 ring for OSN2500 The switching is initiated by 2 means;
1. Laser Shutdown
2. Physically Removing Patch Cord
RX trigger condition on SDH analyzer is AU_AIS. Laser Shutdown shows the switching time on SDH analyzer 100% of the time without any problem. 
While removing the patch cord; sometime the switching time is shown and sometime it is not shown on the SDH analyzer. 
Alarm Information
APS_INDI
Handling Process
1. check the analyzer results for diffrent speed of patch unplug
2. results vary from 1ms to 2,000 msec
3.think that patch removal is BER generator before R_LOS
4. check the ITU standard for switching time
Root Cause
The switching time as stipulated by the ITU-T recommendations excludes the switching detecting time. Usually, the test result includes the switching detecting time. The SF detecting time is usually less than 2 ms, the B2OVER 1E3-3 detecting time is 10 ms, and the SD switching detecting time (1E-6) is 10 s. 
Suggestions
when we make MSP switch time check need to differs between SD switch and SF switch conditions

END