How to replace the T2SL64 boards in MSPR configuration with N1SL64 board

Publication Date:  2012-07-25 Views:  40 Downloads:  0
Issue Description
The T2SL64 (BOM 03030CUN01) boards in MSPR configuration have to be replaced with N1SL64 (BOM0 3030BNT107) boards in OSN 7500.  A document is required for this activity. The NE version is 5.21.13.47P02.
Alarm Information
Null
Handling Process
1. Select the correct backup board. N1SL64 can supports the board version replacement function, so you can simply remove the old ID board and insert the new ID board. The new ID board automatically uses the ID of the old ID board and works normally. No settings are required. After the new ID board is inserted, the board resets before it enters the normal working state because there is a negotiation process between the board and the NE software. The board works normally after a period of time about 3 to 4 minutes.
2. Query current alarms on T2000. You should confirm there is no any abnormal alarm, if not, please handles the abnormal alarm firstly.
3. Query the network protection configuration. Use the NM to query whether the equipment is configured with protection. If it is not configured, go to step 5. The following are the steps that are related to querying the MSP. 
a.Choose Configuration > Protection View from the Main Menu. Select Protection View > SDH Protection Subnet Maintenance. 
b.Choose a subnet configured with the MSP from the list box on the left. The state of the nodes on the subnet is indicated in the list box on the right. 
c.Click Query to check the switching state of a particular node. 
4. In the case of no switching, initiate the switching on the T2000. The following are the steps that are related to initiating the MSP switching. 
a.Right-click the NE icon and select NE Explorer. 
b.Choose Function Tree > Configuration > Ring MS . 
c.Right-click the board to be replaced, and select Exercise-Ring switching from the shortcut menu. An Operation Result dialog box is displayed. Click Close.
d.Click Query > Query Switching State. If the state of Exercise-Ring switching is displayed, it indicates the MSP switching is normal. 
e.Query the alarms and performance events on the NM. Check whether there are no new alarms and performance events and services are normal. If yes, it indicates that the switching is successful. 
f.Right-click the board to be replaced, and select Forced Switching to Protection-Ring. An Operation Result dialog box is displayed. Click Close. 
g.Click Query > Query Switching State from the shortcut menu. If Forced Switching is displayed, it indicates that the switching is successful. 
5. Replace the faulty board. 
6. Release the MSP switching by using the NM. 
a.Right-click the NE icon and select NE Explorer. 
b.Choose Function Tree > Configuration > Ring MS . 
c.Select the board that is being replaced. Choose Clear from the shortcut menu. An Operation Result dialog box is displayed. Click Close. 
d.Click Query > Query Switching State. If Normal is displayed, it indicates that the switching is disabled. 
7. Verify whether the fault is rectified. Query board alarms and confirm that the original alarms are cleared. Perform and verify exercise switching.
Root Cause
Null
Suggestions

Null