Fault process can't start

Publication Date:  2012-07-25 Views:  64 Downloads:  0
Issue Description
After installation of N2000 system on Windows platform, Fault process can't start.
Alarm Information
Alarm appears in System Monitor: Fault process can not be started.
Handling Process
1. port 162 has been checked - it is not occupied
2. after reinstall Windows, SQL, N2000 problem was not solved
3. checked available memory in Sysmonitor - it was enough
After LAN cable was connected to Server, Fault process and other was started. The reason was - Fault process checking whether he can receive Trap and he need Interface in Up state.
Root Cause
Possible reasons:
1. port 162 is occupied
2. problems with installation
3. not enough memory
Suggestions
Null