Both RSP Normal but Frame was failed.

Publication Date:  2012-07-25 Views:  71 Downloads:  0
Issue Description
I was facing a problem in UA5000 F02A, the problem occurs in slave frame.Two RSP cards installed in the slave frame when both cards connected in the frame RSP cards show normal on the CLI Terminal but but other cards like A32, DSL,SDL other service cards become failed on the same frame.When i take out any one RSP card from the frame all service cards become normal.
Alarm Information
service cards was showing failed on CLI Terminal.
Handling Process
When i checked cables at the baclplane of the control cards i saw two cables connected to PV4 cards and two cable connected to RSP when i uninstalled the cables which were connected to the RSP then all service card become normal and both RSP cards and service cards show normal on the CLI terminal.
Root Cause
step 1: I check the frame link of RSP cards but it was ok.
step 2: I installed other RSP cards on the slave frame but the behaviour was same.
step 3: I check the fuses of the frame but that were ok.
step 4: I check the cables at the backplane of the control cards of master and frames.
Suggestions
Null