FAQ-Can the NetStream Function Be Configured on the NE80E and the NE5000E in IP-Trunk Interface Mode

Publication Date:  2012-07-27 Views:  50 Downloads:  0
Issue Description

Q:

Can the NetStream function be configured on the NE80E and the NE5000E in IP-trunk interface mode?

Version: NE80E V3R2   NE5000E V2R2

IP trunk is configured between the NE80E and the NE5000E.

If a trunk interface is configured, can the NetStream function be enabled in IP-trunk port mode, or does the function still need to be configured in POS physical interface mode?
Alarm Information
Null
Handling Process

A:

In IP-trunk interface mode, add the POS interface to the IP trunk. The NetStream function, however, cannot be configured in physical interface mode. This function is restricted. Only the 2800 board supports this function. The restrictions are as follows:

Supports only inbound interface statistics.

Supports only fixed-packets sampling mode.

Supports up to 1000 NetStream resources.

Supports only unicast IPv4 packet statistics.
Root Cause
Null
Suggestions
Null