No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

A loose EMU cable causes UA5000 prompt 8 power feed digits alarm.

Publication Date:  2012-07-25 Views:  64 Downloads:  0
Issue Description
During the project deployment, Partner reported one site 8 -48V Switch alarm, but they could confirm the 4 power feeds connection were normal.
When you log into system, you can check it as following
UA5000(config)#display emu                                                      
{ <cr>|emuid<U><0,63> }:                                                        
  Command:                                                                      
          display emu                                                           
  EMU parameter                                                                 
  ----------------------------------------------------------------------------  
  ID Type    State  |ID Type    State  |ID Type    State  |ID Type    State     
  ----------------------------------------------------------------------------  
   0 H801ESC Normal |16 -       -      |32 -       -      |48 -       -         
   1 FAN     Normal |17 -       -      |33 -       -      |49 -       -         
   2 FAN     Normal |18 -       -      |34 -       -      |50 -       -         
   3 FAN     Normal |19 -       -      |35 -       -      |51 -       -         
   4 FAN     Normal |20 -       -      |36 -       -      |52 -       -         
   5 -       -      |21 -       -      |37 -       -      |53 -       -         
   6 -       -      |22 -       -      |38 -       -      |54 -       -         
   7 -       -      |23 -       -      |39 -       -      |55 -       -         
   8 -       -      |24 -       -      |40 -       -      |56 -       -         
   9 -       -      |25 -       -      |41 -       -      |57 -       -         
  10 -       -      |26 -       -      |42 -       -      |58 -       -         
  11 -       -      |27 -       -      |43 -       -      |59 -       -         
  12 -       -      |28 -       -      |44 -       -      |60 -       -         
  13 -       -      |29 -       -      |45 -       -      |61 -       -         
  14 -       -      |30 -       -      |46 -       -      |62 -       -         
  15 -       -      |31 -       -      |47 -       -      |63 -       -         
  ----------------------------------------------------------------------------  
                          
UA5000(config)#interface emu 0                                                  
UA5000(config-if-h801esc-0)#display esc alarm                                   
  EMU ID: 0                             ESC alarm information                   
  ----------------------------------------------------------------------------  
  AnalogID Name                 Alarm   |AnalogID Name                 Alarm    
     0     Temperature          Normal  |   1     Input_-48V_0         Normal   
     2     Input_-48V_1         Normal  |   3     Input_-48V_2         Normal   
     4     Input_-48V_3         Normal  |   5     -                    Normal   
     6     -                    Normal  |   7     -                    Normal   
     8     -                    Normal                                          
  ----------------------------------------------------------------------------  
  DigitalID Name                Alarm   |DigitalID Name                Alarm    
     0     Wiring               Normal  |   1     Door0                Alarm    
     2     -                    Normal  |   3     -                    Normal   
     4     -                    Normal  |   5     -                    Normal   
     6     -                    Normal  |   7     -                    Normal   
     8     -                    Normal  |   9     Water_Alarm          Normal   
     10    Arrester 0           Normal  |   11    Arrester 1           Normal   
     12    Arrester 2           Normal  |   13    Arrester 3           Normal   
     14    -48V SW11            Alarm   |   15    -48V SW12            Alarm    
     16    -48V SW21            Alarm   |   17    -48V SW22            Alarm    
     18    -48V SW31            Alarm   |   19    -48V SW32            Alarm    
     20    -48V SW41            Alarm   |   21    -48V SW42            Alarm    
     22    Outer Sensor Power   Normal                                          
  ----------------------------------------------------------------------------  The 8 power switches are Alarm. 
UA5000 version is UA5000IPMBV100R015C02B077
Alarm Information
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  16    EMU Type:        
  H801ESC    Name:  -48V SW21                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  17    EMU Type:        
  H801ESC    Name:  -48V SW22                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  18    EMU Type:        
  H801ESC    Name:  -48V SW31                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  19    EMU Type:        
  H801ESC    Name:  -48V SW32                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  20    EMU Type:        
  H801ESC    Name:  -48V SW41                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:30 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  21    EMU Type:        
  H801ESC    Name:  -48V SW42                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:32 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  14    EMU Type:        
  H801ESC    Name:  -48V SW11                                                   
UA5000(config-if-fan-1)#                                                        
! FAULT MAJOR 2008-07-29 01:08:32 ALARM NAME :Digital abnormal alarm            
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  15    EMU Type:        
  H801ESC    Name:  -48V SW12              
The Alarm of BMS, please see attached picture for detail.
Handling Process
Normally, if the power feeds are faulty, you can see the red led from the front panel of SPDA. When I am on site, I have checked this panel; power feed light is green and normal. Then I have checked the power switch setting. The setting and software configuration were correct. The last option, I have unscrewed the top fix of UA5000 High density rack, I have found the monitor cable connection was loose and cause this issue. From the following picture, you can see the J1 connection is loose, when I plugged it back. The 8 power feeds alarm was gone and system was normal.
So I can sure the root reason was the loose J1 connection cause the UA5000 could not detect the power feed and generate this digit alarm
Root Cause
Possible reason are 8 power feeds are faulty, the power switch are set wrong or power feeds monitor cable is wrong. 
Normally, if the power feeds are faulty, you can see the red led from the front panel of SPDA. When I am on site, I have checked this panel; power feed light is green and normal. Then I have checked the power switch setting. The setting is correct, meantime, I have checked software configuration, configuration is correct as while. The last option, I have unscrewed the top fix of UA5000 High density rack, I have found the monitor cable connection was loose and cause this issue. From the picture inside the attachment, you can see the J1 connection is loose, when I plugged it back. The 8 power feeds alarm was gone and system was normal.
Suggestions
If we can understand more about the UA5000 power structure and relevant function, we can analysis and locate the power feed issue soon.

END