No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Real Maximum traffic capacity on Ethernet port

Publication Date:  2012-07-25 Views:  24 Downloads:  0
Issue Description
On interface fast Ethernet of MA5300 V100R006B01D107 presents packet loss due the high to high traffic peaks. When check the port performance by N2000 V200R008B02D061SP018 only observe peaks of 80% of traffic. 
Alarm Information
Null
Handling Process
Is necessary to change link to GigaEthernet port or add a link-aggregation group with other Ethernet ports in order to improve BW of the link.  
Root Cause
Check the port performance (one Fast Ethernet port) by N2000 and they notice about some problems in traffic because the ping from PC connect to ADSL port to a PC has many lost packets but only observe peaks of 80% of traffic. Finally made link aggregation with two FastEthernet port and the lost of packets was solve. The real problem was that the stream traffic which by the BMS showed just is payload rate ,doesn't is the total traffic.  The formula to calculate the total bandwidth is:
Actual bandwidth of uplink port(100M)= [preamble frame(7byte)+Start Frame Delimiter(1byte)+length of message +frame gap(at least 12byte)×8 
Suggestions
BMS only shows the payload rate. So to calculate the total bandwidth use the formula:
Actual bandwidth of uplink port(100M)= [preamble frame(7byte)+Start Frame Delimiter(1byte)+length of message +frame gap(at least 12byte)×8 

END