Alarm generated time differ from alarm arrive time

Publication Date:  2012-07-25 Views:  26 Downloads:  0
Issue Description
In R11 version, there is a new parameter in alarm list: arrive time
Generated time should be a little earlier than arrive time, should not be later than the arrive time.
But in fact, there are so many alarm with the problem that generated time later than arrive time.
Alarm Information
Null
Handling Process
1. Before change the DST of the BMS server, N2000 BMS service and SQL service must be stopped, otherwise the alarm data can't be trapped to the BMS server.
2. Chanage the DST setting consistent with the one of the host.
3. Reboot the Windows system.
Root Cause
The BMS server DST is inconsistent with the host setting
Suggestions
null 