Issue Description
Q:
How to set new digital alarm with H303ESC in UA5000?
Remark: UA5000 version is PVU8 V100R011B02D055.
Alarm Information
Null
Handling Process
A:
Use esc digital command to config the alarm in the host.The first 20 alarms are for the system default, others 21~52 are the user-defined alarm.
huawei(config-if-h303esc-0)#esc digital 
{ digitalid<U><0,21> }:10 
{ available_level<E><low-level,high-level>|digital_alarm<K> }:low-level 
{ <cr>|name<S><0,19> }:name 
Command: 
esc digital 10 low-level name 
EMU fault, offline configuration succeeds  
As for the cable connection and relation between ESC digital ID and EMU ports, please see the attachment.