No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

The unused space in the VPR configuration table haven't been initialed that caused save-operation overrun 7 minutes

Publication Date:  2012-07-25 Views:  43 Downloads:  0
Issue Description
 Control Board - SCUA Version:MA5600V800R003C02B108SP001.
MA5600T MSAN maincontroller-board, SCUA, saved software process of database overrun 7 minutes.
Alarm Information

Null

Handling Process
We have followed these steps on maincontroller board: 
1.save configuration
2.active configuration (need to reboot system)
3.save configuration once more after system rebooted to check the problem is solved.
Root Cause
This problem was generated by the unused space in the VPR configuration table of maincontroller board's database. It hadn’t been initialed, which will induce system have to read some random value and spend a long time during compression-phase.
Suggestions

Null

END