How to create GE end to end in OSN6800V1R3

Publication Date:  2012-07-25 Views:  39 Downloads:  0
Issue Description
OSN6800V1R3C02B01e, when we want to create GE end to end service after och level trail created, it promote wrong. There is no service trail for creating GE end to end.We couldn't create the GE trail.
Alarm Information
NO.
Handling Process
When we want to create GE end to end service, we should do the trail search before the och level trails were created.
Root Cause
We need OTU5G trails before creating GE end to end trails. The OTU5G trails can be searched after the och level trails were created.
Suggestions
 When we want to create end to end trail, we shall do the trail search first.