FAQ-How to avoid the error when adding the second multi-PVC for a port in BMS

Publication Date:  2012-07-25 Views:  12 Downloads:  0
Issue Description

Q:

When the customer tries to add the second PVC in a port SHDSL for an IPoA solution and this port has the option MULTI-PVC enables the next errors appear.
Add PVC failed.
Failure cause: The Vlan ID has been used in other PVC of this port.
The N2000 has the version V200R010C02B015

Alarm Information
Add PVC failed.
Failure cause: The Vlan ID has been used in other PVC of this port.
Handling Process

A:

Because when you add new PVC don’t exist the option to choose the type of PVC is necessary made the next procedure:
The first PVC of the port change the configuration of the PVC, the type  IPoA and the VLAN we need to use with his inner VLAN
Then add the second PVC with the info by default that the PVC has. (with out change the VLAN)
After that the second PVC is created and we change the configuration of that PVC, the  type  IPoA and the VLAN we need to use with his inner VLAN.
And the same process to create more PVC.

Root Cause
The reason of this fault is because when you create the second PVC for the port by default the system created this PVC with a 1483B LLC type; This kind of PVC type don’t permit create a solution that consist in Multi-PVC with the same the VLAN  with different inner VLAN.
Suggestions

Null