FAQ-How to Clear All Alarm Statistics in the Fault Browser of the N2000 BMS

Publication Date:  2012-07-25 Views:  20 Downloads:  0
Issue Description
Q:
How to clear all alarm statistics in the fault browser of the N2000 BMS? 
 
Alarm Information
Null
Handling Process
A:
The quantity of alarm records displayed by the alarm statistics in the fault browser is the sum of alarm records in the current alarm database and those in the history alarm database. Every time the fault browser is opened, the alarm statistics are refreshed once. To clear all the alarm statistics, you need to confirm and move the alarm statistics in the current alarm database to the history alarm database, and then dump out the history alarm database so that the current alarm database and the history alarm database are empty. Then, open the fault browser and you can find the alarm statistics are all cleared. 
 
Root Cause
Null
Suggestions
Null