AU_LOP was observing on protection board because no 1+1 Linear MS was configured on the interconnected equiptment

Publication Date:  2012-07-25 Views:  45 Downloads:  0
Issue Description
AU_LOP was observing on 16-N1SL16. Every thing was re-checked and found ok. There was 1+1 Linear MS created between 3-SL16 and 16-SL16. There was further connectivity of 3-SL16 and 16-SL16 of OSN7500 with Siemens HIT 7070/Dual Core. Connectivity was like that
OSN End------------HIT End
03-N1SL16 with 101IFS2G5
16-N1SL16 with 102IFS2G5
Alarm Information
AU_LOP on 16-N1SL16
Handling Process

1) Check that Linear MS 1+1 on both sides
2) Check the parameters like WRT and Revertive/Non-Revertive in Linear MS on both sides (OSN and HIT)

3) After creating Linear MS 1+1 protection at siemens HIT end alarms from OSN were successfully cleared. 

Root Cause

After further analysis it was found that Linear MS 1+1 was not created at HIT end between their STM boards. Due to this, at OSN end services were successfully mapped on protection board which is 16-N1SL16, but at siemens HIT end as there was no Linear MS 1+1 so no services were mapped on protection board. Due to which the protection board of OSN was showing AU_LOP alarm. 

Suggestions
1)-In the discussed case, ensure 1+1 protection on both equipments. 
2)-The concatenation level of the services transmitted at the opposite end is inconsistent with that of the services to be received at the local end.

END