Registration Report Problem of Board Highest Rate Level ODUk_LOFLOM Alarm

Publication Date:  2012-07-25 Views:  62 Downloads:  0
Issue Description
1. The tributary/line integrated boards LDG/LQM/L4G and the line board NS2 are registered with alarms indicating the highest rate. For example, the LDGD board is registered with the ODU1_LOFLOM alarm and the NS2 board is registered with the ODU2_LOFLOM alarm. And you can query the registration information for the abovementioned ODUk_LOFLOM alarms of the boards on the T2000.
2. The tributary boards TDG/TQM/TQS are registered with the ODU1_LOFLOM alarm that can be reported. 
 
Alarm Information
Null  
Handling Process
No handling. 
Root Cause
1. The tributary/line integrated boards LDG/LQM/L4G and the line board NS2 are registered with the alarms indicating the highest rate. These alarms, however, are not actually reported. Related documents and the T2000 indicate that these alarms are supported. There is no other impact.
2. The tributary boards TDG/TQM/TQS are registered with the ODUk_LOFLOM alarm that can be reported. According to the OTN recommendations, the board need not report the highest rate level ODUk_LOFLOM alarm. But, the alarm reporting is helpful for the fault location. The capability of the tributary board of reporting the ODUk_LOFLOM alarm is reserved. 
 
Suggestions
Null 

END