When the SCC Board in V1R3 Is Not Loaded with the License, the SYSTEM_DEF_RUNNING Alarm Is Reported

Publication Date:  2012-07-25 Views:  27 Downloads:  0
Issue Description
When the SCC board in V1R3 is not loaded with the license, the SYSTEM_DEF_RUNNING alarm is reported. 
Alarm Information
Null  
Handling Process
The ASON features are optional for the V1R3 users, and the problem can be solved according to the practical situations.
1. If the users do not need the ASON function, set the alarm to be unmonitored.
2. If the ASON function is needed, the users should purchase a license and load it to clear the SYSTEM_DEF_RUNNING alarm. And then the ASON features are available. 
 
Root Cause
The SYSTEM_DEF_RUNNING alarm indicates that the SCC board is not loaded with a license, and the ASON features are unavailable at this moment. 
Suggestions
Null 