When a Warm Reset Is Performed on the TN11TBE Board, the COMMUN_FAIL Alarm Is Reported. After the Board Becomes Normal, the Alarm Is Cleared. Why

Publication Date:  2012-07-25 Views:  49 Downloads:  0
Issue Description
When a warm reset is performed on the TN11TBE board, the COMMUN_FAIL alarm is reported. After the board becomes normal, the alarm is cleared. Why? 
 
Alarm Information
Null 
Handling Process
After the warm reset for the board software is completed, the COMMUN_FAIL alarm is cleared. 
 
Root Cause
The detection mechanism for the COMMUN_FAIL alarm: If the NE software detects that the DMM communication with the board is unavailable for more than seven seconds, it reports the COMMUN_FAIL alarm.
During the warm reset on the board, the communication between the NE software and the board is unavailable and the warm reset takes two minutes. As a result, the COMMUN_FAIL alarm is generated.
After the warm reset for the board software is completed, the DMM communication between the NE software and the board becomes normal. Thus, the COMMUN_FAIL alarm is cleared. 
 
Suggestions
Null 