No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-After the TN11TBE Board Is Configured with a Static Forwarding Table, Delete the VLAN Filter List, a Momentary Broadcasting Service Occurs. Why

Publication Date:  2012-07-25 Views:  52 Downloads:  0
Issue Description
Q:
After the TN11TBE board is configured with a static forwarding table, if you delete the VLAN filter list, a momentary broadcasting service occurs on the TN11TBE board. 
 
Alarm Information
Null 
Handling Process
A:
The sequence of deleting the VLAN filter list: the NE software firstly issues the command to delete the static forwarding table, and then issues the command to delete the VLAN filter list. That is, the static MAC forwarding table is deleted before the deletion of the VLAN filter list, and the messages are not filtered. Then, the broadcast of services occurs transiently. 
 
Root Cause
Null 
Suggestions
Null 

END