How to Clear the Board Alarms on the NE80E V300R002C06B325

Publication Date:  2012-07-27 Views:  58 Downloads:  0
Issue Description
When you pull the board out of the NE80E after pressing the OFL button or run the offline command to cut off the power, the equipment gives an alarm "LPU9 is pulled out". In fact, no board is inserted at slot 9 at the time. Although all services run normally, the alarm indicator on the master MPU is on. How to clear the alarm? 
 
Alarm Information
<r2>dis alarm all
---------------------------------------------------------------------------
Level        Date          Time             Info

Alert       08-07-08    23:37:50       LPU9 is pulled out
---------------------------------------------------------------------------- 
 
Handling Process
1. Run the following commands to clear the alarm:
[r2]_h
[r2-hidecmd]clear alarm slot 9
<r2>dis al al
----------------------------------------------------------------------------
NO alarm
----------------------------------------------------------------------------
2. Clear the alarm by resetting the integrated equipment. 
 
Root Cause
Null
Suggestions
Null