FAQ-What Are the Differences Between Different Versions of NE80E in Configuring Port Mirroring

Publication Date:  2012-07-27 Views:  52 Downloads:  0
Issue Description
Q:
What are the differences between different versions of NE80E in configuring port mirroring? 
 
Alarm Information
Null
Handling Process
A:
1. The way to configure port mirroring is the same for V300R001 and V300R002.
First, configure the mirroring monitor port in the system view. Then, enable port mirroring in the mirror port view.
Suppose GigabitEthernet7/0/7 is the monitor port and GigabitEthernet3/0/0 is the mirroring port. Do as follows to configure port mirroring:
#
observe-port 1 interface GigabitEthernet7/0/7---Designate the monitor port.
#
interface GigabitEthernet3/0/0
port-mirroring to observe-port 1 inbound---Enable port mirroring.
#
2. It is a bit different for V300R003.
First, access the interface view to designate the interface as the mirroring monitor port (the index number of the monitor port must be consistent with the slot number of the LPU where the port is). Then, access the slot view to configure the monitor port for the mirroring function of the board. Finally, enable port mirroring in the mirroring port view.
Suppose GigabitEthernet7/0/7 is the monitor port and GigabitEthernet3/0/0 is the mirroring port. Do as follows to configure port mirroring:
interface GigabitEthernet7/0/7
port-observing observe-index 7---Designate the monitor port.
#
slot 3
mirror to observe-index 7―Observe the port and bind the monitor port with the board.
#
interface GigabitEthernet3/0/0
port-mirroring inbound---Enable port mirroring.

 
Root Cause
Null
Suggestions
Null

END