FAQ-How to Clear Alarms Generated When a Board Is Pulled out of the NE40E

Publication Date:  2012-07-27 Views:  53 Downloads:  0
Issue Description
Q:
How to clear alarms generated when a board is pulled out of the NE40E? 
 
Alarm Information
Null
Handling Process
A:
For the NE40E and NE80E of the current versions, alarms informing the board extraction are left when boards are pulled out of the device. In addition, the alarm indicator on the SRU/MPU permanently on. There alarms do not affect the normal running of devices, but often cause misunderstandings. In V300R002C06B335 and later versions, the system provides the following commands to clear these alarms:
[Quidway]_h
[R1_NE80E-hidecmd]clear alarm slot x
In terms of V300R003, V300R003C02B321 and later versions provide the command to clear these alarms. 