NE40E - LPU with 5 Giga Optical interfaces is not register.

Publication Date:  2012-07-27 Views:  65 Downloads:  0
Issue Description
The board "CR52E5GF0 5-port GbE SFP Optical Interface LPU A" install in NE40E router doesn't register.
Alarm Information
Dec 5 2008 14:41:11 RD-BOG-RTDN %%01SRM/4/ECMLOGIN(l): MPU send the information of product type to slot3 successfully
#Dec 5 14:41:27 2008 RD-BOG-RTDN SRM_BASE/1/ENTITYREMOVE:OID 1.3.6.1.4.1.2011.5.25.129.2.1.1 Physical entity is removed. (EntityPhysicalIndex=196608, BaseTrapSeverity=6, BaseTrapProbableCause=65537, BaseTrapEventType=5, EntPhysicalContainedIn=0, EntPhysicalName="LPU slot 3 ")
Dec 5 2008 14:41:27 RD-BOG-RTDN %%01SRM/3/LPUPULLOUT(l): LPU3 is pulled out.
#Dec 5 14:41:52 2008 RD-BOG-RTDN SRM_BASE/4/ENTITYINSERT:OID 1.3.6.1.4.1.2011.5.25.129.2.1.2 Physical entity is inserted. (EntityPhysicalIndex=196608, BaseTrapSeverity=4, BaseTrapProbableCause=65536, BaseTrapEventType=5, EntPhysicalContainedIn=0, EntPhysicalName="LPU slot 3 ")
Dec 5 2008 14:41:53 RD-BOG-RTDN %%01SRM/3/LPUPLUGIN(l): LPU3 is plugged in.
Dec 5 2008 14:41:57 RD-BOG-RTDN %%01SRM/3/MBUSREG(l): Slot3 MonitorBUS node registered.
Dec 5 2008 14:42:18 RD-BOG-RTDN %%01SRM/3/PWRONFINISH(l): Slot3 board power-on finished.
Dec 5 2008 14:42:52 RD-BOG-RTDN %%01SRM/4/ECMLOGIN(l): MPU send the information of product type to slot3 successfully
Handling Process
Udgrade VRP Version in LPU board by command:
<Quidway>upgrade lpu by-testbus "slot" cfcard:/vrp_name.cc lpu_bootload.
Root Cause
Some VRP versions need to upgrade the software in some LPU boards by command.
Suggestions
 

END