No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-What Precautions Should Be Taken in the Deployment of Dual Control Boards of the MA5680T

Publication Date:  2012-07-25 Views:  50 Downloads:  0
Issue Description
Q:
What precautions should be taken in the deployment of dual control boards of the MA5680T? 
 
Alarm Information
Null
Handling Process
A:
Two control boards are configured on the MA5680T. After the active control board is started normally, when the standby control board is started, an alarm is displayed, indicating that the MAC address of the standby control board is different from that of the active control board. This problem need not be solved manually. The standby control board restarts automatically, changes its MAC address to be the same as that of the active control board, and synchronizes all data with that of the active control board. This process takes approximately 20 minutes. 
 
Root Cause
Null
Suggestions
Null

END