FAQ-How to Handle the Problem of Slow Query Speed on the Client Due To the Cutover or Expansion of Substantive Devices on the N2000 BMS R008

Publication Date:  2012-07-25 Views:  42 Downloads:  0
Issue Description
Q:
How to handle the problem of slow query speed on the client due to the cutover or expansion of substantive devices on the N2000 BMS R008? 
 
Alarm Information
Null
Handling Process
A:
After substantive devices are cut over on the N2000 BMS, it is slow to query the ADSL and Service Port windows and to open the device panel. This is a known problem of the Sybase. To solve the problem, you need to manually update statistics of tables that include substantive data.
To enter the isql, run the following command:
#isql -Usa -PXXX -SN2000DBServer ----//XXX refers to the password of user Sa.
Run the following scripts:
use BMSDB
go
update all statistics ma5600v3_adsl_PortTab
go
update all statistics ma5600v3_pvc_CxcTab
go
update all statistics ma5600v3_pvc_VplVclTab
go
update all statistics ma5600v3_pvc_SrvFlowTab
go
update all statistics ma5600v3_gdm_ObjectTab
go
The table names of the pvc and adsl in the preceding scripts can be changed according to the NE types, such as ma5600tv8 and ma5100v2. 
 
Root Cause
Null
Suggestions
Null