FAQ-How to Set the Parameter for the Function of Automatically and Periodically Discovering EPON Devices on the N2000 BMS

Publication Date:  2012-07-25 Views:  24 Downloads:  0
Issue Description
Q:
The N2000 BMS V200R011C16B032 that manages EPON devices provide the function of Auto-Discover. In the dialog box, however, only the Time Discover Setting option is available. Can the parameter be modified? 
 
Alarm Information
Null
Handling Process
A:
You can modify the parameter manually. Modify "#period auto start time,Format:Hour+Minute+Second(HHMMSS)"
in the server/conf/emfsecu.cfg file.
AutoTime = 023000 // Change the time according to the preceding format.
The modification takes effect after you restart the topology daemon. 
 
Root Cause