FAQ-Can the Monitored State of NEs on the N2000 BMS R011 Be Changed to the Running State

Publication Date:  2012-07-25 Views:  42 Downloads:  0
Issue Description
Q:
Can the monitored state of NEs on the N2000 BMS R011 be changed to the running state? 
 
Alarm Information
Null
Handling Process
A:
When adding a device, select Status. The status description is as follows:
In Service: When the device is in the in service state, the alarms of the device are successfully reported to the N2000 BMS in the normal state.
Out of Service by Maintenance: When the device is in the out of service by maintenance state, the alarms of the device are not reported to the N2000 BMS. Pre-deployed: When the device is in the pre-deployed state, the device is virtual. The out of service by maintenance state cannot be changed to the in service state directly. You must delete the device, and select the in service state when adding the device again.
The pre-deployed state can be changed in to the in service state automatically, if the device is configured correctly and the device and the N2000 BMS communicate in the normal state. 
 
Root Cause
Null
Suggestions
Null

END