FAQ-why the statistic of master is more than sum of all the accounting level in DAA service in ME60

Publication Date:  2012-07-27 Views:  33 Downloads:  0
Issue Description
Q:
in ME60, the customer configurate only DAA service, but when they check the log file and find out that the sum statistic of all the traffic in different accounting level is smaller than the master statistic, why?
Alarm Information
the statistic in different accounting level:
Acct-Input-Octets = 1641763
Acct-Output-Octets = 71101
hw-Accounting-Level = 5
Acct-Input-Octets = 0
Acct-Output-Octets = 0
hw-Accounting-Level = 4
Acct-Input-Octets = 0
Acct-Output-Octets = 0
hw-Accounting-Level = 3
Acct-Input-Octets = 1749
Acct-Output-Octets = 12163
hw-Accounting-Level = 2
Acct-Input-Octets = 93
Acct-Output-Octets = 250
hw-Accounting-Level = 1
so the sum is:
input Octets =1643605
output Octets=83514
master:
Acct-Input-Octets = 1644329
Acct-Output-Octets = 84528
Handling Process
A:
we can check there is about 1000 bytes traffic in those statistic between master and sum.
this traffic is the information before DAA user online.  in this status, the user information of authentication and communication can not be calculated by DAA statistic but  master will calculate it. 
we can confirm it by continuing observational.
after the user online, the customer download a lot files, but  the difference of the packet number does not increase.
it approved that all the data traffic is calculated by the DAA statistic.
Root Cause
Null
Suggestions
 Null

END