No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-How to Define the Tid Template of the MA5620E

Publication Date:  2012-07-25 Views:  39 Downloads:  0
Issue Description
Q:
The MA5620E whose version is V800R305C01B026 supports configurations, such as the defined tid template, integer, hierarchy, and whether to add fixed natural numbers. How to do the configurations? 
 
Alarm Information
Null
Handling Process
A:
The tid of the MA5620E consists of tid prefix and tid template.
Where, tid prefix is a fixed string.
The configuration is as follows:
MA5620E(config-if-h248-0)#tid-format pstn prefix <PSTN prefix>
MA5620E(config-if-h248-0)#tid-format rtp prefix <RTP prefix>
In addition, tid template is configurable. Templates 0�17 are provided with the system and cannot be configured. Templates 32�63 are defined templates.
The configuration is as follows:
MA5620E(config)#tid-template add 32 format <format expression> parameter-list <format expression> name <template name>
The format expression supports the following:
Integer format: %u, format of integer with the same bits: %02u, hierarchy format: %u/%u/%u, format of hierarchy with the same bits: %02u/%02u/%02u
The parameter expression supports the following:
Natural number (G), natural number + fixed number (G + x). This expression is used with the integer format expression together.
Frame/slot/port (F/S/P), frame + fixed number/slot + fixed number/port + fixed number (F + x/S + x/P + x).
Therefore, tidname is a consecutive string that is calculated according to tid prefix and tid template. 
 
Root Cause
Null
Suggestions
Null

END