FAQ-What Precautions Should Be Taken in Configuring the Digital Map When a Device Is Interconnected to the Softswitch of Company Z

Publication Date:  2012-07-25 Views:  44 Downloads:  0
Issue Description
Q:
What precautions should be taken in configuring the digital map when a device is interconnected to the softswitch of company Z? 
 
Alarm Information
Null
Handling Process
A:
1. Timer S cannot be placed at the end of the digital map.
2. A period (.) cannot be placed after S directly.
3. The separator | cannot be placed at the beginning or end of the digital map. 
 
Root Cause
Null
Suggestions
If an incorrect digital map is configured, the AG returns the error 400.
SS->AG
(contextid=0 handle=577)
!/1 [10.35.1.254]:2944 T=406404987{C=-{MF=A3{E=402833927{dd/ce{DM=dmap1},al/*},SG{cg/dt},
DM=dmap1{
(18xS.| (This corresponds to the error of preceding point 2.)
9xxxxS| (This corresponds to the error of preceding point 1.)
013xxxxxxxxx|
010xxxSxxxxx|
02xxxxSxxxxx|
057[147]xxxSxxxxx|
059[15]xxxSxxxxx|
[2-8][1-9]xxxxxx| (This corresponds to the error of preceding point 3.)
)}}}}
AG->SS
(contextid=0 handle=577)
MEGACO/1 [10.35.211.66]:2944 ER=400{"Syntax error in message"} 
 

END