The Existing Board Could Not Be Normally Registered After the NE80 Was Upgraded to VRP3.10-2358

Publication Date:  2012-07-27 Views:  35 Downloads:  0
Issue Description
 After the NE80 was upgraded from VRP3.10-2321 to VRP3.10-2358, the 100 M board (cr-16xfe-e-rj45) with 24 electrical interfaces at a certain slot could not be registered as usual and this board kept rebooting. 

 
Alarm Information
slot 8 is updating bootrom.please do NOT take it out or reset it!!!
slot 8 .Loading file is OVER!.
Download of software to LPU board on slot 8 has failed
MPU occurs error, error Code:20, Error message:The maximum times resend data expire. 

 
Handling Process
After the patch was loaded to the upgraded device, the board can be normally registered. 

 
Root Cause
After the upgrade, you need to download the interface program to the LPUs from the MPU and then write the program to the flash. However, the interval for such writing is only 5s. In the case of timeout, the MPU automatically resets the boards. Owing to the constant expansion of the interface program and the slow writing of the program to the flash by the existing board, the LPUs are reset once and again. In the 2358 patch, the interval for such writing is prolonged. 

 
Suggestions
Generally, in the upgrading process, the patch is loaded after the boards are registered. However, after the NE80 is upgraded to a certain version, some existing boards can be registered only after the patch is loaded. 

 