Issue Description
Problem Description:
Error found during configuration.
Mode Error of Ethernet port, Error Code: 38774.
Alarm Information
Mode Error of Ethernet port, Error Code : 38774 during configuration.
Handling Process
Configure the GE port (Port 1 and Port 2) of EGS2 either 1000M Full Duplex or Auto-Negotiation only. 
Change Working Mode to both Auto Negotiation for Port 1 and Port 2.
Then no more error.
Root Cause
Cause Analysis:
After analysis found that configuration for Working Mode is set mix for Port 1 and Port 2. Port cannot configured one 1000M Full Duplex and other one Auto_Negotiation. It must be same.
The GE port of EGS2 can support either 1000M Full Duplex or Auto-Negotiation only. 
See screen capture in Attachments.
Suggestions
Null