'Fail to Protection' status in Linear MSP when an interconnected equipment was involved

Publication Date:  2012-07-25 Views:  39 Downloads:  0
Issue Description
In customer's network there is made Linear 1+1 MS between 5-SLQ4-3 and 14-SLQ4-3 on OSN7500. Furter it is connected with third party S company equipment. After configuring Linear 1+1 MS on OSN and S company equipment, the status of Linear MS on OSN7500 was "fail to Protection" for 15-SLQ4-3. It was quite confusing at OSN7500 because all parameters were correctly assigned and power values was also in normal range. 
Alarm Information
APS_INDI
MS_APS_INDI_EX
Handling Process
After analysis, the problem was found in configuration of third party equipment. On OSN7500 Linear MS was configured Dual-Ended Switching but on S company equipment it was configured as Unidirectional. The conventions is like that:
S company equipment============OSN7500
Uni-directional -------------------------------Single-Ended Switching
Bi-directional----------------------------------Dual-Ended Switching
After Uni-directional is reconfigured to Bi-directional on Siemens HIT, problem was solved and status was "Idle"
Root Cause
Check the followings,
1) Power values of 4-SLQ4 and 15-SLQ4 should be normal
2) Check the Power values on interconnected equipment
3) Linear 1+1 MS parameters should be correctly assigned on both ends
Suggestions
In cases like above, make sure the configurations on both equipments should match and compatible. 