No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

how to clear the alarm of SYNC_C_LOS on OSN3500.

Publication Date:  2012-07-25 Views:  39 Downloads:  0
Issue Description
there is a ring on the new network but some NEs have the alarm of SYNC_C_LOS
Alarm Information
Null
Handling Process
1.check the external clock is ok and some of the NE do not have the alarm
2.check Clock Subnet Configuration ,found the SSM Protocol stoped if we start the SSM Protocol the alarm cleared.
Root Cause
1.external clock problem
2.Clock Subnet Configuration problem
3.board problem
Suggestions
Null

END